EPOTEC PU PARK

A seamless three-component system intended for large-capacity parking areas, resistant to salts, oil substances, frost, and water, serving as a foundation construction for indoor areas. The economical line Epotec PU SYSTEM with a slight bridging of cracks, suitable for indoor areas

Advantages

  • ductile, mechanically and chemically resistant, flexible waterproofing membrane
  • suitable for concrete and asphalt
  • anti-skid surface
  • solvent-free
  • possibility of colour combinations
  • reasonable price

Laying technology

Surface preparation – Concrete

Shot-blasting, grinding, or milling All non-adhesive particles must be removed so that the surface is clean, dry, dust-free, and open-structured. The surface must not be contaminated with oils or any other substances.
For penetration, use Epotec PU Primer or Epotec Primer SF, depending on the condition of the concrete.
Highly porous surfaces may require 2 layers of penetration. Depending on the local conditions and on the state of the foundation, Epotec Primer SF or Epotec Primer SW may also be used.

Surface preparation – Asphalt

Shot-blasting providing a good texture and removing all impurities. For penetration, use Epotec PU Primer.

Mixing

Packages are pre-weighed in order to achieve optimal results during application. Never divide or change the batches in the package. Avoid too much air from entering the mixture. Mix in a dry environment to prevent humidity from entering the mixture.

Application – Epotec PU Primer

Immediately after mixing all the components, spread the material with a rake or a notched trowel so that the layer is even. The material is self-levelling. Before applying Epotec PU Finish, sprinkle silica sand of fraction 0.3 – 0.8 (depending on the required grain size) thoroughly over the entire surface. After hardening, remove all non-adhesive particles with a broom and a vacuum cleaner.

Epotec PU Finish

Immediately after mixing, spread the material with a rubber spreader or a notched trowel and roll over with a roller.

Other information

If other products are to be used in connection with this material, consult the relevant technical data sheets in order to determine all possible risks.

Certificates

Epotec PU Park meets the requirements specified in Government Regulation 163/2002 Coll. The material has been tested and certified by competent authorities. A Certificate issued by an Authorized Body confirms the quality of the material. Products placed on the market are compliant with the technical specifications.
The following documents concerning Epotec PU Park are available:

  • Certificate in accordance with the provisions of Article 10 of Act 22/1997 Coll., on the technical requirements for products and amendment of certain acts, as amended, and Article 5 of Government Regulation 163/2002 Coll., as amended by Government Regulation 312/2005 Coll.
  • Product Certification Report in accordance with Act 22/1997 Coll., on the technical requirements for products, as amended, and Article 5 of Government Regulation 163/2002 Coll
  • Construction Technical Certificate in accordance with the provisions of Article 10 of Act 22/1997 Coll., on the technical requirements for products and amendment of certain acts, as amended, and Article 2 and 3 of Government Regulation 163/2002 Coll., as amended by Government Regulation 312/2005 Coll.
  • Test Reports in compliance with the following standards: ČSN EN ISO 527–4,2, ČSN EN ISO 604, ČSN 744507, ČSN 731324, ČSN 736242, ČSN 732577, ČSN EN ISO 868
  • Tests of fire technical characteristics in compliance with the following standards: ČSN EN 13501–1, ČSN EN ISO 9239–1, ČSN EN ISO 11925–2, ČSN EN 730810
  • Determination of volatile organic compounds (VOC) – Testing method of a specialized site – The National Institute of Public Health, Prague

Work safety

  • Irritates eyes, respiratory organs and skin.
  • Sensitisation may occur on inhalation and contact with skin.
  • Dangerous for the environment.
  • Sensitisation may occur on contact with skin.
  • Do not inhale gas/fume/vapour/spray.
  • Wear suitable protective clothing, gloves and eye/face protection.
  • After contact with skin, wash immediately with plenty of water.
  • In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice.
  • This material and its container must be disposed of as hazardous waste.
  • In the case of insufficient ventilation, use suitable equipment to protect your respiratory system.
  • Call for medical attention immediately in the case of an accident or if you feel unwell (if possible, show this label).
  • Extremely toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment.
  • Avoid leakage to the environment. See special instructions / safety data sheets.
  • Harmful if inhaled.

StrukturaStruktura

Ke staženísample

Certificates
Determination of... (542 Kb)
Anti-slip properties (663 Kb)
Fire Tests -... (3 Mb)
Bridging Of... (1 Mb)
Certification... (2 Mb)
Declaration of... (344 Kb)
Test Report -... (3 Mb)
Certificate (351 Kb)
Construction... (1 Mb)
Protocol on fire... (783 Kb)
Wholesomeness (2 Mb)
Report on the... (1 Mb)

Documents
ISO 9001:2008 (576 Kb)
ISO 14001:2004 (581 Kb)
Technical Data... (143 Kb)
Technical Data... (137 Kb)

Safety Lists
Epotec PU... (139 Kb)
Epotec PU... (149 Kb)
Epotec PU Finish... (133 Kb)
Epotec PU Finish... (184 Kb)
Epotec PU Primer... (140 Kb)
Epotec PU Primer... (179 Kb)
Epotec PU Primer... (132 Kb)

logo moody

Introduction | About Us | Areas Of Application | Types Of Floors | Products | References | Contact
Company: TECHFLOOR S. R. O., Company offices: Roztoky, 17.Listopadu 454, Zip Code 252 63,
ID No.: 253 50 650, Date of record: May 14, 1996
All rights reserved Techfloor

cz | en |
print

webdesign by TOMATO / powered by PLANIX